Title: Comparison of predicted and measured oxygen levels in a semi-closed underwater breathing apparatus.
Authors: Nuckols, ML
Finlayson, WS
Newville, B
Gavin, WA Jr
Keywords: diving
rebreather
underwater breathing apparatus
semi-closed
oxygen
US Divers Aqualung OxyMix
exhaust volume ratios
breathing bellows
prediction
optimisation
physiological models
diluent injection system
exercise
Issue Date: 2001
Publisher: IEEE
Citation: Nuckols ML, Finlayson WS, Newville B, Gavin, Jr WA. Comparison of predicted and measured oxygen levels in a semi-closed underwater breathing apparatus. OCEANS, 2001. MTS/IEEE Conference and Exhibition. 5-8 Nov. 2001 pages 1725 - 1730 vol.3
Abstract: An analytical model has recently been developed for predicting the circuit oxygen levels in semi-closed underwater breathing apparatus at various mission depths and diver activity levels (Nuckols, Clarke, Marr, 1999). Unmanned testing in June 2000 with a commercially available US Divers Aqualung OxyMix rebreather (NEDU Test Plan Number 00-06 dated May 2000) showed good agreement with this analytical model over a wide range of diver depths, orientations and activity levels (Nuckols, Gavin, Finlayson, 2000). However, the model indicated that an enhanced performance capability could possibly be achieved with the OxyMix by modifying the size of its exhaust bellows and changing the oxygen content of the supply gas. Following the tests in June, an optimization approach was applied to the analytical model to define desired design parameters for the OxyMix rebreather to maximize its excursion depth capability. Optimized exhaust volume ratios (EVR), the ratio of the small inner bellows volume relative to the main breathing bellows, and supply gas oxygen concentrations were identified to maximize safe operations for the OxyMix design. US Divers agreed to fabricate two modified exhaust bellows of varying volumes for testing to verify the predicted performances of the modified OxyMix rebreather. During the week of 18 December 2000, unmanned testing with these modified OxyMix rebreathers at the Experimental Dive Facility at NEDU verified predicted performances. Specific findings in these tests included a) a modified OxyMix rebreather using an exhaust volume ratio of approximately 6.25% and a supply gas mixture containing 37% oxygen was shown to give an excursion capability to 130 FSW while maintaining circuit PO2 levels below 1.32 Ata (excursions to 150 FSW were shown to be possible with maximum PO2 levels below 1.6 Ata) b) similar to the results seen in the June tests, circuit PO2 levels were shown to be unaffected by diver activity rates between RMV's of 22.5 LPM and 62.5 LPM c) the addition of a diluent injection system on the modified OxyMix design provided minimum circuit oxygen levels of 0.42 Ata at 20 FSW and 0.25 Ata at 0 FSW while still maintaining circuit PO2 levels below 1.32 Ata for excursions up to 130 FSW
Description: Copyright © 2001 IEEE.
URI: http://archive.rubicon-foundation.org/7960
ISBN: 0-933957-28-9
Appears in Collections:Institute of Electrical and Electronics Engineers, Inc. (IEEE)

Files in This Item:

File Description SizeFormat
IEEE_Oceans2001_7231360.pdf871KbAdobe PDFView/Open

All items in DSpace are protected by copyright, with all rights reserved.

 

  Copyright © 2004-2006 Rubicon Foundation, Inc. - Feedback